TM 55-1520-240-23-7
8-101
INSTALL HYDRAULIC MAINTENANCE PANEL COMPONENTS
(Continued)
8-101
10.
Install aft transmission low oil pressure time
delay relay as follows:
a.
Remove tag and install relay (44) in panel (2).
b.
Install three nuts (45) and washers (46).
c.
Install tubing (E431) over four wires (47).
d.
Solder four wires (47) to relay terminals (48).
Use solder (E360). Remove tags.
e.
Slide tubing (E368.1) over relay terminals
(48) and shrink with heat gun.
f.
Tie wires (47). Use lacing tape (E403) (TM
55-1500-323-25).
8-327