TM 55-1520-240-23-7
8-101
INSTALL HYDRAULIC MAINTENANCE PANEL COMPONENTS
(Continued)
8-101
INSPECT
NOTE
Procedure is the same to install 10
diodes and 30 terminal modules.
Installation of TB1-1/2 is shown here.
4.
Install TB1-1/2 module as follows:
a.
Install module (14) in mounting track (5).
Make sure A pin (15) location is at upper left.
When installing modules in TB2 through TB5,
make sure A pin location is at lower left.
b.
Connect 10 wires (16) to module (14). Use
contact insertion/removal tool. Remove tags.
c.
Tie wires (16). Use lacing tape (E403) (TM
55-1500-323-25).
5.
Install UTILITY HYDRAULIC RESERVOIR
LEVEL check switch as follows:
a.
Remove tag and install switch (17) in panel
(2) from inside.
b.
Install nut (18) and washer (19).
c.
Install tubing (E431) over wires (20).
d.
Solder two wires (20) to switch terminals (21).
Use solder (E360). Remove tag.
e.
Slide tubing (E431) over switch terminals (21)
and shrink with heat gun.
f.
Tie wires (20). Use lacing tape (E403) (TM
55-1500-323-25).
8-322