TM 55-1520-240-23-7
8-101
INSTALL HYDRAULIC MAINTENANCE PANEL COMPONENTS
(Continued)
8-101
NOTE
Procedure is the same to install
TRANSMISSION CHIP DETECTOR,
DEBRIS SCREEN, OVERTEMP,
and ENGINE CHIP DETECTION
INDICATORS. Installation of
FORWARD TRANSMISSION CHIP
DETECTOR INDICATOR is shown
here.
8.
Install FORWARD TRANSMISSION CHIP
DETECTOR INDICATOR as follows:
a.
Install indicator (36) in panel (2) from inside.
b.
Install lockwasher (37) and nut (38).
c.
Install tubing (E431) over four wires (39).
d.
Solder four wires (39) to indicator terminals
(40). Use solder (E360). Remove tags.
e.
Slide tubing (E431) over indicator for
terminals (40) and shrink with heat gun.
f.
Tie wires (39). Use lacing tape (E403) (TM
55-1500-323-25).
8-325