TM 55-1520-240-23-7
8-101
INSTALL HYDRAULIC MAINTENANCE PANEL COMPONENTS
(Continued)
8-101
NOTE
Procedure is same to install
GND RESET/TEST and FLIGHT
CONTROL HYDRAULIC RESERVOIR
LEVEL SELECT SWITCH. Installation
of GND RESET/TEST SWITCH is
shown here.
7.
Install GND RESET/TEST SWITCH as follows:
a.
Install locking ring (28) on switch (29). Make
sure tab (30) of locking ring faces away from
switch.
b.
Remove tag and install switch (29) in panel
(2) from inside. Make sure that tab (30) of
locking ring (28) is in locator notch (31) of
switch mount hole (32).
c.
Install lockwasher (33) and nut (34).
d.
Connect five wires (35). Use contact
insertion/removal tool. Remove tags.
e.
Tie wires (35). Use lacing tape (E403) (TM
55-1500-323-25).
8-324