TM 55-1520-240-23-7
8-101
INSTALL HYDRAULIC MAINTENANCE PANEL COMPONENTS
(Continued)
8-101
NOTE
Procedure is the same to install the
TRANSMISSION MAIN OIL and
AUX OIL PRESS, FILTER CHANGE,
PUMP FAULT, and, on helicopters
with 25 , GROUND CONTACT
indicator lights. Installation of the
FWD TRANSMISSION AUX OIL
PRESS indicator light is shown here.
6.
Install indicator light as follows:
a.
Remove tag and install light base (22) in
panel (2) from inside.
b.
Install lockwasher (23) and nut (24).
c.
Install tubing (E431) over three wires (25).
d.
Solder three wires (25) to light terminals (26).
Use solder (E360). Remove tags.
e.
Slide tubing (E431) over light terminals (26)
and shrink with heat gun.
f.
Tie wires (25). Use lacing tape (E403) (TM
55-1500-323-25).
g.
Install lens (27) on light base (22).
8-323