TM 55-1520-240-23-7
8-101
INSTALL HYDRAULIC MAINTENANCE PANEL COMPONENTS
(Continued)
8-101
NOTE
Procedure is the same to install
HYDRAULIC PRESSURE
TEMPERATURE and RESERVOIR
LEVEL INDICATORS. Installation
of No. 1 FLIGHT CONTROL
HYDRAULIC PRESSURE
INDICATOR is shown here.
9.
Install No. 1 FLIGHT CONTROL HYDRAULIC
PRESSURE INDICATOR as shown:
a.
Clean bonding surface of indicator (41). Use
cloth (E120).
b.
Install space (42) on indicator (41).
c.
Remove tag and install indicator (41) in panel
(2) (TM 55-1520-240-10).
d.
Tighten round head clamp screw (4).
e.
Connect electrical connector (43) to indicator
(41). Remove tag.
8-326