TM 55-1520-240-23-7
8-101
INSTALL HYDRAULIC MAINTENANCE PANEL COMPONENTS
(Continued)
8-101
12.
Install WORK LIGHT as follows:
a.
Remove tag and position base (53) on panel
(2).
b.
Install two screws (54) and washers (55).
c.
Install work light (56) in base (53).
d.
Install grommet (57) in panel (2).
e.
Route two work light wires (58 and 59)
through grommet (57).
f.
Route black work light wire (58) to T54 (60)
module 7 (61). Insert wire into pin socket (7).
Use contact insertion/removal tool.
g.
Route white work light wire (59) to TB4 (60)
module 6 (62). Insert wire into pin socket F.
Use contact insertion/removal tool.
h.
Position clamp (63) and install screw (64)
and washer (65).
i.
Tie work light wires (58 and 59) to wire
harness (19). Use lacing tape (E403) (TM
55-1500-323-25).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
8-329