TM 55-1520-240-23-7
8-101
INSTALL HYDRAULIC MAINTENANCE PANEL COMPONENTS
(Continued)
8-101
NOTE
Procedure is the same to install
UTILITY or No. 1/No. 2 FLIGHT
CONTROL hydraulic system level
SIGNAL CONDITIONER. Installation
of UTILITY hydraulic system level
SIGNAL CONDITIONER is shown
here.
11.
Install UTILITY hydraulic system level SIGNAL
CONDITIONER as follows:
a.
Clean bonding surfaces of signal conditioner
(49). Use cloth (E120).
b.
Position signal conditioner (49) and install
four screws (50) and washers (51). Remove
tag.
c.
Connect electrical connector (52) to signal
conditioner (49). Remove tag.
8-328