TM 55-1520-240-23-9
11-64
CLEAN THRUST CONTROL (REMOVED) (AVIM)
11-64
INITIAL SETUP
Applicable Configurations:
All
Tools:
Low Pressure Air Supply
Brush
Materials:
Dry Cleaning Solvent (E162)
Cloths (E120)
Tape (E388)
Gloves (E186)
Personnel Required:
Medium Helicopter Repairer
Inspector
Equipment Condition:
Off Helicopter Task
Task 11-61
General Safety Instructions:
Dry cleaning solvent (E162) is
combustible and toxic. It can irritate
skin and cause burns. Use only with
adequate ventilation, away from open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
1.
Remove dirt and dust from pivot block (1), shaft
(2), and stop (3). Use brush then cloth (E120)
moist with solvent (E162).
2.
Move block (1) and repeat step 1 for shaft (2).
3.
Clean block (1), shaft (2), and stop (3) with
solvent (E162). Use gloves (E186).
4.
Dry block (1), shaft (2), and stop (3). Use cloth
(E120) and low pressure air. Use gloves (E186).
INSPECT
FOLLOW-ON MAINTENANCE:
Assemble thrust control (Task 11-65).
END OF TASK
11-290