TM 55-1520-240-23-3
4-113
INSTALL AND RIG GAS PRODUCER CONTROL LINKAGE
(Continued)
4-113
2.
Measure distance between centers of holes (3)
in rod end bearings (4 and 5). If length is same
as dimension A found in step 1, go to step 3. If
not, do the following:
a.
Remove lockwire and loosen nut (6).
b.
Rotate rod end bearing (4) until distance
between centers of holes (3) is same as
dimension A.
c.
Make sure rod ends (4 and 5) are aligned.
d.
Tighten nut (6).
NOTE
Nominal distance between centers of
holes in rod ends is 13.16 to 13.28
inches.
Do not lockwire nut at this time.
3.
Make sure No.1 ENG COND lever (7) is at STOP.
4-400