TM 55-1520-240-23-9
11-82
INSTALL COPILOTS COCKPIT CONTROL ASSEMBLY
(Continued)
11-82
Acetone (E20) can form toxic
vapors if exposed to flame. Use in
well-ventilated area, away from open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
77.
Clean sealant from flange (120) and inside
surface (121) of access (7). Use acetone (E20)
and cloths (E120). Wear gloves (E186).
78.
Support left landing light housing (122). Remove
strap (123).
Sealant (E336) can irritate skin and
cause burns. Avoid contact with skin,
eyes, and clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
79.
Apply sealant (E336) to both sides of gasket
(124). Install gasket on flange (120). Remove
excess sealant with acetone (E20) and cloths
(E120). Wear gloves (E186).
80.
Tilt housing (122) and position inside access
(7), lamp (125), aft. Align housing and access
holes (126).
81.
Repeat steps 77 thru 80 for right housing (127).
11-436