Do not exceed 160ºF (71ºC) at pod
surface. Damage to pod can occur.
13.
Cure adhesive at 140º to 160ºF (60º to 71ºC)
for 2 hours. Use explosion-proof heat lamp
set 11 to 12 inches from insert (6). Monitor
temperature with temperature indicating strips
(E413).
NOTE
Serviceable cure can be achieved
without heat at 70º to 80ºF (21º to
27ºC) in 24 hours.
14.
Remove tab (8).
INSPECT
15.
Smooth any adhesive deposit around insert (6).
Use abrasive paper (E7).
Epoxy primer (E292.1) is flammable
and toxic. It can irritate skin and
cause burns. Use only with adequate
ventilation, away from heat or open
flame. Avoid contact with skin, eyes,
or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
16.
Touch up area around insert (6) as needed with
epoxy primer (E292.1).
FOLLOW-ON MAINTENANCE: