TM 55-1520-240-23-4
5-118
CLEAN REMOVED SWASHPLATE
5-118
INITIAL SETUP
Applicable Configurations:
All
Tools:
Fiber Brush
Goggles
Materials:
Cloth (E120)
Dry Cleaning Solvent (E162)
Gloves (E186)
Personnel Required:
Medium Helicopter Repairer
Equipment Condition:
Off Helicopter Task
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Do not use excessive solvent (E162).
Too much solvent can wash foreign
material into bearing and seal areas.
1.
Clean swashplate (1). Use cloth (E120) fiber
brush, and solvent (E162). Wear goggles. Wear
gloves (E186).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
Change 1 5-666.5/(5-666.6 blank)