• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
REPLACE  TIP  END  CAP (Continued)
TIP  SEAL  MAJOR  REPAIR  (AVIM) (Continued)

TM-55-1520-240-23-4 CH-47D Heilcopter Manual
Page Navigation
  432    433    434    435    436  437  438    439    440    441    442  
TM  55-1520-240-23-4 5-77 TIP  SEAL —  MAJOR  REPAIR (AVIM) 5-77 INITIAL  SETUP Applicable Configurations: All Tools: Airframe  Repairer’s Tool Kit, NSN 5180-00-323-4876 Vacuum  Cleaner Materials: Abrasive  Paper  (E7) Gloves  (E186) Cloth  (E120) Acetone  (E20) Teflon  Tape  (E399) Aluminum  (E70) Sealant  (E336) Masking  Tape  (E388) Wood  Spatula  (E424) Personnel  Required: Aircraft  Structural  Repairer Inspector Reference: TM  55-1520-240-23P Equipment  Condition: Off  Helicopter  Task General Safety Instructions: Acetone (E20) is extremely flammable. It  can  be  toxic.   Avoid  inhaling.   Use only with  adequate  ventilation. Avoid  contact  with  skin,  eyes,  or clothing.   Keep  away  from  heat, sparks,  or  open  flame.   In  case  of contact, immediately flush skin  or eyes with  water for  at  least  15 minutes. Get medical  attention  for eyes. Adhesive  used  in  the  manufacturing of some  fiberglass  rotor blades  contain asbestos.   During  blade  repair,  strict adherence  to  all  safety  procedures when  working  with  asbestos  must be  complied  with  (applies to  blade serial  numbers A-1-0001  to  1465  and A-2-0001  to  1473  only). 5-441