TM  55-1520-240-23-4 5-76 INBOARD RIB  CLOSURE  AND  TIP SEAL MINOR REPAIR (Continued) 5-76 17. Vacuum  bag  the  repair as  follows: a. Cover  repair  with  a  sheet of peel  ply (E270) (6) and  a  sheet  of  Teflon-impregnated  fabric (E170)  (7).   Cut  material  large  enough  to overlap  repair 1 inch  in  all  directions.  Hold  in place  with  masking  tape  (E388). b. Cover repair with  fiberglass  cloth  (E132) (8). c. Surround  cloth  (8) with  sealing  tape  (E396) (9).   Keep  tape  clear of  cloth. d. Attach  tube  (10) to  vacuum  pump  hose. Wrap  two  layers  of  cloth  (E132)  around tube.  Secure  cloth  to  tube  with  masking  tape (E388). e. Position  tube  (10) on  cloth  (E132).  Wrap  tube with  sealing  tape  (E396)  (11)  where  tube crosses sealing  tape  (9) already  applied. f. Press  tube  (10)  onto  tape  (9) to  make  airtight seal. 5-437