  435    436    437    438    439  440  441    442    443    444    445  
TM  55-1520-240-23-4 5-77.1 REPLACE  LIGHTNING PROTECTION  JUMPER WIRE 5-77.1 INITIAL  SETUP Applicable  Configurations: All Tools: Airframe  Repairer’s Tool  Kit, NSN  5180-00-323-4876 Torque  Wrench,  5  to  50  Inch-Pounds Materials: Sealant  (E336) Acetone  (E20) Cloth  (E120) Abrasive  Paper  (E9) Naphtha  (E245) Lacquer,  Black,  Lusterless  (E215) Lacquer  Thinner  (E415) Gloves  (E184.1) Personnel  Required: Aircraft  Structural  Repairer Inspector References TM  55-1500-344-23 Equipment  Condition: Battery Disconnected  (Task  1-39) Electrical  Power  Off Hydraulic  Power  Off One  Forward  and  One  Aft  Rotary-Wing  Blade  Tied Down  (Task  1-26) Work  Platform  Open  (Task  2-2) Ensure  that  blade  surface  is  not damaged  during  sealant removal. NOTE Procedure  is  same  to  remove  any of 12  lightning  protection  jumper  wires. REMOVE  JUMPER WIRE 1. Remove  sealant from  bolt  (1)  and  jumper  wire (2).   Use  utility  knife  and  chisel. 5-444