TM 55-1520-240-23-7
9-98.3
REPAIR OVERHEAD PANELS
(Continued)
9-98.3
RECEPTACLE
NOTE
The receptacle in all panels is
replaced in the same manner.
TROOP WARN/HEATING panel
shown here.
4.
Remove receptacle (19) as follows:
a.
Remove lightplate (12). (Refer to step 2.)
b.
Turn fasteners (20) 1/4 turn counterclockwise.
Pull panel (8) away from overhead panel (1)
far enough to gain access to receptacle (19).
c.
Remove screw (21) and washer (22).
Remove wire (23). Tag wire with tag (E264).
d.
Remove nut (24), lockwasher (25), and
ground lug (26).
e.
Remove receptacle (19) from panel (8).
5.
Install receptacle (19) as follows:
a.
Insert a serviceable receptacle (19) in panel
(8).
b.
Inspect wire on ground lug (26). Install lug,
lockwasher (25), and nut (24) on receptacle
(19).
c.
Inspect wire (23). Install wire, washer (22),
and screw (21). Remove tag.
d.
Position panel (8) on overhead panel (1).
Turn fasteners (20) 1/4 turn clockwise to
secure panel.
e.
Install lightplate (12). (Refer to step 3.)
9-348