TM 55-1520-240-23-6
7-88.1
REMOVE EXTENSIBLE LINK SELF FEEDBACK TRANSDUCER (AVIM)
(Continued)
7-88.1
NOTE
Removal of transducer can be
performed on No. 1 or No. 2
extensible link installed on actuator
or with extensible link removed from
actuator. No. 2 extensible link on
actuator is shown.
1.
Remove lockwire from two screws (1) of bracket
(2).
2.
Remove screw (3) from wire (4) and bracket (2).
Remove wire.
3.
Remove lockwire from locknut (5). Remove
locknut from receptacle (6).
4.
Remove receptacle (6) from bracket (2).
5.
Cut and remove strap (7) from backshell (8).
6.
Remove backshell (8) from receptacle (6).
7.
Tag and disconnect four wires (9) from pins
No. 1, 2, 3, and 4 of backshell (8). Use
removal/insertion tool.
8.
Cut and remove strap (10) from support (11).
9.
Remove lockwire from retainer (12) and washer
(13). Remove retainer, turn counterclockwise.
10.
Remove two washers (13 and 14).
11.
Remove lockwire from support (11) and link
body (15). Remove support by turning it
counterclockwise.
7-358