TM 55-1520-240-23-6
7-88.2
INSTALL EXTENSIBLE LINK SELF FEEDBACK TRANSDUCER (AVIM)
(Continued)
7-88.2
2.
Pass cable (4) through support (5). Install
support in body (2). Torque support to 150
inch-pounds.
3.
Pass cable (4) through washer (6) smooth
surface inward. Mount washer on support (5),
tang (7) in slot (8) of support.
4.
Pass cable (4) through washer (9) smooth
surface outward. Mount washer on transducer
(1) with tang (10) in slot (11).
5.
Pass cable (4) through retainer (12). Mount
retainer (12) on transducer (1). Do not tighten.
Washers (6 and 9) must be apart.
6.
Adjust extensible link self feedback transducer
(1) (Task 7-101).
INSPECT
NO BREAK - WORK HARDER
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-361