TM 55-1520-240-23-6
7-49
ASSEMBLE ACCUMULATOR (2770529) (AVIM)
7-49
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Strap Wrench, 15/16 to 5-9/16 Inches
Crowfoot Wrench, 1 Inch
Torque Wrench, 700 to 1600 Inch-Pounds
Depth Gage, 0 to 0.125 Inch
Source of Low Pressure Compressed Air
Soft Jawed Vise
Materials:
Dry Cleaning Solvent (E162)
Hydraulic Fluid (E199)
Cloth (E120)
Lockwire (E227)
Adhesive (E43)
Methyl-Ethyl-Ketone (E244)
Gloves (E186)
Parts:
Packings
Retaining Rings
Personnel Required:
Aircraft Pneudraulics Repairer (2)
Inspector
References:
TM 55-1520-240-23P
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
1.
Clean all parts (1 thru 6) with dry cleaning solvent
(E162). Dry with low pressure compressed air.
Use goggles for eyes. Use gloves (E186).
INSPECT
2.
Cover parts (1 thru 6) with cloth (E120) to keep
off dust and dirt until needed.