TM 55-1520-240-23-6
7-48.2
DISASSEMBLE AND INSPECT ACCUMULATOR (60910) (AVIM)
7-48.2
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Technical Inspection Tool Kit, NSN 5180-00-323-5114
Outside Micrometer Calipers, 1 to 2 Inch
Telescoping Gage Set
Soft Jawed Vise
Materials:
None
Personnel Required:
Aircraft Pneudraulics Repairer
Inspector
References:
Task 7-1.1
Equipment Condition:
Off Helicopter Task
General Safety Instructions:
Release gas and fluid pressures
before disassembling, storing, or
shipping accumulator. Maximum
operating pressure is 3,350 psi.
NOTE
General inspection criteria (Task
7-1.1) for obvious damage applies
unless otherwise stated.
Inspection steps cover parts that are
subject to wear.
1.
Install gas port end of accumulator (1) in vise (2).
7-233