TM 55-1520-240-23-6
7-49
ASSEMBLE ACCUMULATOR (2770529) (AVIM)
(Continued)
7-49
Methyl-ethyl-ketone (E244) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Adhesive (E43) can irritate skin and
cause burns. Avoid contact with skin,
eyes, and clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
24.
If shell (1) is being replaced or nameplate (23)
was removed, install nameplate as follows:
a.
Clean shell (1), nameplate (23), and strap
(24) with methyl-ethyl-ketone (E244). Use
cloth (E120).
b.
Apply adhesive (E43) to all contact surfaces
between shell (1), nameplate (23), and strap
(24).
c.
Wrap nameplate (23) and strap (24) around
shell (1). Interlock by running strap through
nameplate and bending as shown.
FOLLOW-ON MAINTENANCE:
Test accumulator (Task 7-50).
END OF TASK
7-241