TM 55-1520-240-23-6
7-321
FLUSH GROUND TEST, PUMP, HAND PUMP, AND RESERVOIR PRESSURE
TUBING
(Continued)
7-321
14.
Remove four bolts (22) and washers (23) from
accumulator mount (24). Disconnect two tees
(25 and 26) from mount. Remove mount.
15.
Install plug (27) in pressure tee (25).
16.
Install plug (28) in return tee (26).
17.
Disconnect fitting (29) from EMERG UTIL
PRESS valve (30).
18.
Disconnect tube (31) from valve (30).
19.
Connect hose (32) to tube (31) and fitting (29).
20.
Disconnect tubes (33 and 34) from UTIL
RESERVOIR REPRESSURIZE valve (35).
21.
Connect hose (36) to tubes (33 and 34).
7-1156