TM 55-1520-240-23-6
7-321
FLUSH GROUND TEST, PUMP, HAND PUMP, AND RESERVOIR PRESSURE
TUBING
(Continued)
7-321
36.
Disconnect hose (40) from port (43) of reservoir
(41). Use cloths (E120) for spilled fluid.
37.
Connect tube (42) to PRESS port (43) of
reservoir (41).
38.
Working from ramp, disconnect hose (40) from
pump (39). Remove hose. Use container and
cloths (E120) for spilled fluid.
39.
Connect tube (37) to PRESS port (38) of pump
(39).