INSTALL TIEDOWN RECEIVER (Continued)
5-81
5.
Taper adhesive (5) around receiver (2). Spread
adhesive until it extends 1/4 inch from receiver.
Use additional adhesive, if necessary.
CAUTION
Blade temperature must not exceed
160 F (71 C). Overheating will
damage fiberglass.
6.
Cure repair at 140 to 160 F (60 to 71 C)
for 2 hours. Use heat lamp. Monitor blade
temperature. Use temperature indicating strips
(E413).
NOTE
If heat lamp is not available, cure at
70 to 80 F (21 to 27 C) for 24
hours.
INSPECT
FOLLOW-ON MAINTENANCE:
None
END OF TASK