TM 55-1520-240-23-4
5-34
INSTALL VERTICAL HINGE PIN OUTER SEAL
(Continued)
5-34
NOTE
Procedure is same to install outer seal
in all 12 vertical hinge pin oil tanks.
1.
Clean tank (1). Use cloth (E120) damp with dry
cleaning solvent (E162). Wear gloves (E186).
2.
Clean sealant from seal recess (2) in tank (1).
Use methyl-ethyl-ketone (E244). Wear gloves
(E186).
3.
Check tank (1) for cracks. There shall be no
cracks.
4.
Remove protective coating from seal (3). Use
cloth (E120) damp with dry cleaning solvent
(E162). Wear gloves (E186).
5.
Check seal lips (4) for nicks or scratches. Use
magnifier. There shall be no nicks or scratches.
5-158