TM 55-1520-240-23-10
16-109
REMOVE ENGINE AIR PARTICLE SEPERATOR (EAPS)
16-109
INITIAL SETUP
Applicable Configurations:
All
Tools:
General Mechanics Tool Kit, NSN 5180-00-323-4692
EAPS Lifting Device (T188)
Hoist
Vacuum Cleaner
Materials:
Cloth (E120)
Detergant (E159.1)
Personnel Required:
Medium Helicopter Repairer (3)
Equipment Condition:
Battery Disconnected
Electric Power OFF
Hydraulic Power OFF
1.
Remove two nuts (1), washers (2), bolts (3), and
bump stop (4) from forward end of each rail (5).
NO BREAK - WORK HARDER
2.
Disconnect 1/4 turn fastener (6) holding the
electrical cable clamp from aircraft fuselage.
3.
Disconnect plug (7) of electrical cable from
aircraft and attach to dummy receptacle (8)
located on EAPS.
4.
Make sure rails are clean and free from dirt or
grit.
NO BREAK - WORK HARDER
NO BREAK - WORK HARDER
NO BREAK - WORK HARDER
NO BREAK - WORK HARDER
5.
Release 1/4 turn fasteners (6) and remove cross
shaft link (9).
6.
Remove safety clips (10) and open latches on
upper cross shaft seal (11).
7.
Loosen two shoulder bolts (16) and slide upper
cross shaft seal (11) and lower cross shaft seal
(15) seal inboard as far as possible.
16-365