TM 55-1520-240-23-10
16-59.29 OPERATIONAL FLIGHT PROGRAM/MISSION DATA FILE UPLOADING
PROCEDURES (Continued)
16-59.29
6.
Verify MODE (13) and JETTISON (14) switches
on DCDU (11) are off.
7.
Set DCDU MODE switch (13) to STBY.
8.
If required, press the following DCDU INHIBIT
(12) pushbutton switches so that their respective
LEDs are not illuminated: MWS, JMR, RWR, O1,
O2, CH, and FL.
9.
Power up MLV by pressing and holding POWER
switch on keyboard briefly. The MLV LED
indicator illuminates light green or yellow green
and changes to yellow when in power save
mode. If LED does not light, press POWER
switch again. Observe MLV screen to verify that
system boots through MS-DOS and initiates
the Windows software. After boot-up, the MLV
opening screen (Windows Desktop) is displayed.
NOTE
OPF loading will overwrite MDF
memory. If there is no OFP or
incorrect OPF is loaded on the
Programmer, the OFP must be loaded
first before loading the MDF.
16-250.50