TM 55-1520-240-23-10
16-59.29 OPERATIONAL FLIGHT PROGRAM/MISSION DATA FILE UPLOADING PROCEDURES
16-59.29
INITIAL SETUP
Applicable Configurations:
All
Tools:
Electronic Equipment Tool Kit,
NSN 5180-00-064-5178
Universal Memory Loader Verifier (UMLV),
NSN 1680-01-504-6082
Materials:
None
Personnel Required:
Avionics Mechanic (2)
References:
D000 2970 Rev D
OM 3647-40-1
Equipment Condition:
Aircraft Power On (As Required)
Battery Connected
Hydraulic Power Off
LDG GR SW Bypass Switch in Normal
(TM 1-1520-240-10)
ALQ-156 MWS is Off
Load Operational Flight Program (OFP) or Mission Data
File (MDF).
NOTE
Before starting MLV and loading OFP
or MDF, check that the proper OFP
and MDF software version numbers
has been verified with the units
MDF Documentation or unit Aircraft
Survivability Equipment (ASE) officer.
1.
Unpack and set up MLV (1) on flat work surface
near MLV interface port in cabin.
2.
Connect MLV interface cable (4) connector (3) to
the MLV 1553 BUS A port (2) and connector (5)
to the MLV interface port (6).
3.
Apply power to aircraft.
4.
Verify ALE-47 DCDU circuit breaker (CB) (8) on
No. 1 EAPS PDP (7) is in.
5.
Pull out ALE-47 SQUIB PWR NO. 1 (9) and NO.
2 (10) CBs on No. 1 EAPS PDP (7).
Change 1
16-250.49