REMOVE  LINEAR TRANSDUCER  ROD  END BEARING  (AVIM)
INSTALL LINEAR TRANSDUCER ROD END BEARING (AVIM) (Continued)

TM-55-1520-240-23-9 CH-47D Heilcopter Manual
Page Navigation
  681    682    683    684    685  686  687    688    689    690    691  
TM  55-1520-240-23-9 11-173 INSTALL  LINEAR TRANSDUCER ROD  END  BEARING (AVIM) 11-173 INITIAL  SETUP Applicable  Configurations: All Tools: Aircraft Mechanic’s  Tool  Kit,  NSN  5180-00-323-4692 Materials: Antiseize  Compound  (E75) Gloves  (E186) Personnel  Required: Medium  Helicopter Repairer Inspector References: TM  55-1520-240-23P 1. Assemble  nut  (1) on  to  rod  end  (2).  Run  nut  to end  of  thread. 2. Assemble  outer  part (3)  of  locking  device  on  to rod  end  (2).  Serrations (4)  shall  face  away  from nut  (1). 3. Assemble  inner part  (5)  of  locking  device  on  to rod  end  (2).  Serrations  (6) shall  face  serrations (5)  of  outer  part  (3). Antiseize  compound  (E75)  can  form toxic  vapors  if  exposed  to  flame. Use  in  well-ventilated  area,  away from  open  flame.   In  case  of  contact, immediately  flush  skin  or eyes  with water for  at  least  15 minutes.   Get medical  attention  for eyes. 4. Apply  antiseize  compound  (E75) to  threads  of rod  end.  Wear  gloves  (E186). 11-692