TM 55-1520-240-23-9
11-173
INSTALL LINEAR TRANSDUCER ROD END BEARING (AVIM)
11-173
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Materials:
Antiseize Compound (E75)
Gloves (E186)
Personnel Required:
Medium Helicopter Repairer
Inspector
References:
TM 55-1520-240-23P
1.
Assemble nut (1) on to rod end (2). Run nut to
end of thread.
2.
Assemble outer part (3) of locking device on to
rod end (2). Serrations (4) shall face away from
nut (1).
3.
Assemble inner part (5) of locking device on to
rod end (2). Serrations (6) shall face serrations
(5) of outer part (3).
Antiseize compound (E75) can form
toxic vapors if exposed to flame.
Use in well-ventilated area, away
from open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
4.
Apply antiseize compound (E75) to threads of
rod end. Wear gloves (E186).
11-692