• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
INSTALL PITCH  POSITION  TRANSDUCER (Continued) - TM-55-1520-240-23-9_703
INSTALL ROLL LINEAR  TRANSDUCER

TM-55-1520-240-23-9 CH-47D Heilcopter Manual
Page Navigation
  677    678    679    680    681  682  683    684    685    686    687  
TM  55-1520-240-23-9 11-170 REMOVE  ROLL LINEAR  TRANSDUCER 11-170 INITIAL  SETUP Applicable  Configurations: All Tools: Aircraft Mechanic’s  Tool  Kit,  NSN  5180-00-323-4692 Materials: Paper  Tags  (E264) Personnel  Required: Medium  Helicopter  Repairer References: TM  1-1520-253-23 Equipment  Condition: Battery Disconnected  (Task  1-39) Electrical  Power  Off Hydraulic  Power  Off Closet Acoustic Blanket Removed  (Task 2-107) Closet Backup  Panel  Removed  (Task  2-2) NOTE Attaching  bolts, washers, and  nuts  will be  temporarily installed  after  removing transducer. NOTE If  a  crack  in  the  bellcrank  is suspected  during  removal, refer  to  TM 1-1520-253-23. 1. Tag  and  disconnect  two  connectors  (1)  from receptacles (2)  on  structure  (3). 2. Remove  cotter  pin  (4),  nut (5), two  washers (6), and  bolt  (7)  from  support  (8).   Disconnect  roll linear  transducer (9)  from  support and  transducer (10). 3. Install  bolt  (7),  two  washers  (6),  and  nut  (5) loosely  in  support  (8). 4. Remove  cotter  pin  (11),  nut  (12),  two  washers (13),  and  bolt  (14)  from  bellcrank (15).  Remove transducer  (9). 5. Install  bolt (14),  two  washers  (13), and  nut  (12) loosely  in  bellcrank  (15). FOLLOW-ON  MAINTENANCE: None END  OF  TASK 11-688