TEST  HYDRAULIC  RESERVOIR  LEVEL INDICATORS
TEST HYDRAULIC RESERVOIR LEVEL INDICATORS (Continued) TEST  FLIGHT CONTROL HYDRAULIC RESERVOIR INDICATOR

TM-55-1520-240-23-7 CH-47D Heilcopter Manual
Page Navigation
  258    259    260    261    262  263  264    265    266    267    268  
TM  55-1520-240-23-7 8-84 TEST HYDRAULIC RESERVOIR  LEVEL INDICATORS (Continued) 8-84 INDICATOR OUTER SCALE  MARK TEST SET MILLIAMPERE READING 1  (EMPTY) 0 2 .29 3 .38 4  (ADD) .46 6 .48 6 .57 7  (FULL) .65 8 .73 9 .82 10 .90 11 1.00 4. Adjust  test  set  (1)  to  0  milliamperes  (TM 11-6625-277-14). 5. Disconnect indicator (2)  from  test setup. 8-273