TM 55-1520-240-23-7
8-84
TEST HYDRAULIC RESERVOIR LEVEL INDICATORS
(Continued)
8-84
TEST FLIGHT CONTROL HYDRAULIC RESERVOIR
INDICATOR
6.
Adjust meter test set (1) to 0 milliamperes (TM
11-6625-277-14).
7.
Connect flight control hydraulic reservoir indicator
(3) to test setup.
8.
Apply power to test setup and adjust meter test
set (TM 11-6625-277-14). For indicator scale
marks, milliampere readings shall be as follows:
NO BREAK - WORK HARDER
INDICATOR SCALE
MARKS
TEST SET
MILLIAMPERE
READING
1 (EMPTY)
0
2
.33
3
.41
4 (ADD)
.49
5 (FULL)
.58
6
.66
7
.74
8
.82
9
.90
10
1.00
9.
Adjust test set (1) to 0 milliamperes (TM
11-6625-277-14).
10.
Remove power from test setup.
11.
Disconnect indicator (3) from test setup.
FOLLOW-ON MAINTENANCE:
None
END OF TASK
8-274