TM 55-1520-240-23-7
8-82.1
REPLACE FUEL QUANTITY SYSTEM COAXIAL CONNECTOR CONTACTS
(Continued)
8-82.1
26.
Install contact separator (29) on inner contact
(30) flush with end of wire barrel (31).
NOTE
If required, trim cable inner conductor
in order to butt end of contact
wire against cable dielectric before
crimping.
27.
Install inner contact (30) on inner conductor (28)
with end of wire barrel (31) against dielectric (27).
28.
Crimp inner contact (30). Use crimper MH800
with locator K269.
Do not exert more than 1 pound
pressure to seat inner contact.
Damage to contact could occur.
NOTE
After seating inner contact on cable,
support contact and cable until crimp
sleeve is installed to prevent strain on
inner contact crimp joint.
29.
Push inner contact (30) onto contact outer body
(32) until inner contact seats.
8-268