REMOVE LIGHTNING  PROTECTION JUMPER  WIRE  INSERT (Continued)
INSTALL LIGHTNING  PROTECTION JUMPER  WIRE  INSERT (Continued) - TM-55-1520-240-23-4_470

TM-55-1520-240-23-4 CH-47D Heilcopter Manual
Page Navigation
  440    441    442    443    444  445  446    447    448    449    450  
TM  55-1520-240-23-4 5-79 INSTALL LIGHTNING PROTECTION  JUMPER WIRE  INSERT 5-79 INITIAL  SETUP Applicable Configurations: All Tools: Airframe  Repairer’s Tool Kit, NSN  5180-00-323-4876 Installation  Tool  (T25) Heat  Lamp Torque  Wrench,  5  to  50  Inch-Pounds Compressed  Air  Source Materials: Temperature  Indicating  Strips  (E413) Adhesive  (E40  or  E43) Sealant  (E336) Acetone  (E20) Cloth  (E120) Gloves  (E186) Parts: Insert Personnel  Required: Aircraft  Structural  Repairer Inspector References: TM  55-1520-240-23P General Safety Instructions: Adhesive  (E40)  is toxic and can  irritate skin.  Use  in  well-ventilated  area.   In case  of  contact,  immediately  flush skin  or  eyes  with  water  for  at  least 15  minutes.   Get medical  attention for  eyes. 5-449