  425    426    427    428    429  430  431    432    433    434    435  
TM  55-1520-240-23-4 5-76 INBOARD  RIB  CLOSURE  AND  TIP  SEAL MINOR  REPAIR (Continued) 5-76 8. If  inboard  rib  closure  (1)  or  tip  seal  (2)  are  not covered  with  fiberglass,  prepare  the  area  as follows: a. On  tip  seal  (2),  remove  the  tip  cover (Task 5-73). b. Remove  finish  from  rib  closure  (1)  or tip  seal (2)  and  from  surface  of  blade  (3)  for 1 inch in  all  directions.  Use  cloth  (E120) damp  with acetone  (E20).   Wear gloves  (E186). c. Remove  surface  glaze  from rib  closure  (1) or tip  seal  (2) and  exposed  blade  skin  (3).  Use abrasive  paper  (E7). Methyl-ethyl-ketone  (E244)  is flammable.   It  can  irritate  skin  and cause  burns.  Use  only with  adequate ventilation, away  from  heat or open flame.   Avoid  contact  with  skin,  eyes, or  clothing.   In  case  of  contact, immediately  flush  skin  or eyes  with water for  at  least  15 minutes.   Get medical  attention  for eyes. d. Wipe  exposed  area  with  clean  cloth  damp with  methyl-ethyl-ketone  (E244).  Wear gloves (E186). 5-434