  648    649    650    651    652  653  654    655    656    657    658  
TM  55-1520-240-23-3 4-138 REMOVE  POWER TURBINE  CONTROL ACTUATOR 4-138 INITIAL  SETUP Applicable  Configurations: Without   74 Tools: Powerplant  Repairer’s   Tool  Kit,   NSN 5180-00-323-4944 Materials: None Personnel  Required: Aircraft  Powerplant  Repairer Equipment  Condition: Battery Disconnected  (Task  1-39) Electrical  Power  Off Engine  Work  Platform  Open  (Task  2-2) Engine  Access  Cover  Open  (Task  4-49) NOTE Procedure  is  same  to  remove  power turbine  control  actuator  on  No.   1  or No.  2  engine.  No.  1  engine  is  shown here. 1. Disconnect  cable  connector (1) from  actuator (2). 2. Remove  nut  (3) and  washer  (4).   Slide  lever (5) from  shaft  (6).  Move  rod  (7) up  and  aft. 4-450