TM 55-1520-240-23-9
11-220
INSTALL LCT ACTUATOR END FITTING BEARING (AVIM)
(Continued)
11-220
Carbon dioxide (dry ice) (E92)
causes severe burns (frost bite) and
gives off toxic fumes. Use only in
well-ventilated area. Do not get in
eyes, on skin, or clothing. In case of
contact, immediately flush with water.
Get medical attention for eyes.
Methanol (E243) is flammable and
toxic. It can irritate skin and cause
burns. Use only in well-ventilated
area, away from heat and open flame.
In case of contact, immediately flush
skin or eyes with water for at least
15 minutes. Get medical attention
for eyes.
2.
Place bearing (2) in carbon dioxide (dry ice)
(E92) and methanol (E243). Allow bearing to
cool thoroughly. Wear Kevlar gloves (E187).
3.
Support actuator end fitting (3) in arbor press
(4). Anti-rotational lands (5) must face away from
ram (6).
Wear Kevlar gloves (E187) when
handling chilled bearing.
NOTE
Work quickly with chilled bearing. It
must be installed before it warms.
4.
Remove bearing (2) from dry ice. Wipe clean
and dry. Use cloth (E120).
5.
Press bearing (2) into end fitting (3) (TM
55-1500-322-24).
6.
Wipe off excess corrosion preventive compound
from bearing (2) and end fitting (3). Allow bearing
to warm to room temperature.
7.
Roller swage bearing housing (7). Use drill press
and roller staking kit (TM 55-1500-322-24).
INSPECT
FOLLOW-ON MAINTENANCE:
None
END OF TASK
11-864