TM 55-1520-240-23-8
10-112
INSTALL ENGINE FUEL SHUTOFF VALVE
(Continued)
10-112
NOTE
There are two engine fuel shutoff
valves. Procedure is same to install
either valve. No. 2 (right side) valve is
shown here.
1.
Remove plug from tee (1).
2.
Position packing (2) and valve (3) on tee (1).
Install four bolts (4) and washers (5). Lockwire
four bolts. Use lockwire (E231).
3.
Position packing (6) and adapter (7) on valve
(3). Install electrical load (8), four washers (9)
and bolts (10). Lockwire four bolts. Use lockwire
(E231).
4.
Install electrical lead (11), bolt (12) and nut (13)
on flange of tee (1).
5.
Remove plug from hose connector (14). Install
packing (15) in hose connector.
6.
Connect hose connector (14) to adapter (7).
Torque hose connect or to 1125 inch-pounds.
7.
Install clip (16), electrical load (17), two washers
(18), screw (19) and nut (20) on hose connector
(14).
8.
Connect electrical connector (21).
INSPECT
FOLLOW-ON MAINTENANCE:
Perform operational check of fuel system (TM
55-1520-240-T).
Bleed fuel system (Task 10-121).
END OF TASK
10-485