TM 55-1520-240-23-8
10-110
INSTALL DEFUELING MANUAL VALVE
(Continued)
10-110
5.
Tilt tee (5) to vertical position as shown. Tighten
nut (10). Install cap (11) on elbow.
INSPECT
FOLLOW-ON MAINTENANCE:
Bleed fuel system (Task 10-121).
Check for leaks (Task 10-4).
END OF TASK