TM 55-1520-240-23-78-82.1REPLACE FUEL QUANTITY SYSTEM COAXIAL CONNECTOR CONTACTS(Continued)8-82.126.Install contact separator (29) on inner contact(30) flush with end of wire barrel (31).NOTEIf required, trim cable inner conductorin order to butt end of contactwire against cable dielectric beforecrimping.27.Install inner contact (30) on inner conductor (28)with end of wire barrel (31) against dielectric (27).28.Crimp inner contact (30). Use crimper MH800with locator K269.Do not exert more than 1 poundpressure to seat inner contact.Damage to contact could occur.NOTEAfter seating inner contact on cable,support contact and cable until crimpsleeve is installed to prevent strain oninner contact crimp joint.29.Push inner contact (30) onto contact outer body(32) until inner contact seats.8-268