TM 55-1520-240-23-7
8-84
TEST HYDRAULIC RESERVOIR LEVEL INDICATORS
(Continued)
8-84
INDICATOR
OUTER
SCALE MARK
TEST SET MILLIAMPERE
READING
1 (EMPTY)
0
2
.29
3
.38
4 (ADD)
.46
6
.48
6
.57
7 (FULL)
.65
8
.73
9
.82
10
.90
11
1.00
4.
Adjust test set (1) to 0 milliamperes (TM
11-6625-277-14).
5.
Disconnect indicator (2) from test setup.