TM 55-1520-240-23-7
8-82.1
REPLACE FUEL QUANTITY SYSTEM COAXIAL CONNECTOR CONTACTS
(Continued)
8-82.1
Holding Fixture Setup
The holding fixture and adapter or the
smaller holding tool must be used
when soldering to prevent damage
to contacts. When using the smaller
holding tool, the cable must be
secured to prevent cold solder joints.
12.
Install a contact (13) into the appropriate end
of the adapter (18). Pin contact into P end or
socket contact into S end.
13.
Adjust adapter (18) to give a setup dimension of
about 0.25 inches from end of contact (13) to
end of cable clamp (19).
14.
Tighten set screw (21) on back of adapter (18).
Remove contact (13).
Soldering Operation
15.
Position contact (13) and cable (9) through cable
clamp (19).
16.
Install heat shrink sleeving (22) over end of cable
(9).
17.
Check that the cable (9) is fully inserted into the
contact (13).
18.
Insert the contact (13) fully into the adapter (18).
19.
Check that the cable (9) is straight between the
cable clamp (19) and the adapter (18).
8-266