TM 55-1520-240-23-7
8-82.1
REPLACE FUEL QUANTITY SYSTEM COAXIAL CONNECTOR CONTACTS
(Continued)
8-82.1
20.
Position heat gun nozzle (2) and reflector (1) so
that the contact (13) is in the hot air stream.
21.
Direct heat around the front inspection window
(14) and rear inspection window (16) until
the solder preforms melt and flow onto the
conductors, and the insulating sleeve (22)
shrinks around the coaxial cable outer jacket (9).
22.
Remove heat.
INSPECT
ASSEMBLY PROCEDURE FOR CRIMP TYPE
CONTACT
Cable Preparation
23.
Install crimp sleeve (23) over end of coaxial cable
(24).
24.
Prepare coaxial cable (24) by removing outer
jacket (25) and shield (26) to dimensions shown.
25.
Fold back shield (26) and strip dielectric (27)
from inner conductor (28) to dimensions shown.
8-267