TM 55-1520-240-23-67-231REMOVE BRAKE TRANSFER VALVE7-231INITIAL SETUPApplicable Configurations:AllTools:Aircraft Mechanic’s Tool Kit, NSN 5180-00-323-4692Materials:Cloths (E135)Gloves (E186)Personnel Required:Medium Helicopter Repairer (2)Equipment Condition:Battery Disconnected (Task 1-39)Electrical Power OffHydraulic Power OffUtility Hydraulic System Depressurized (Task 7-135.1)Pilot’s and Copilot’s Seats Fully Aft (Task 2-115)General Safety Instructions:Hydraulic fluid (E199) is toxic. It canirritate skin and cause burns. Avoidinhaling. Use only with adequateventilation. Avoid contact with skin,eyes, or clothing. In case of contact,immediately flush skin or eyes withwater for at least 15 minutes. Getmedical attention for eyes.Hydraulic fluid elected under pressurecan cause injury to personnel.Hydraulic fluid sprayed into the air isa fire hazard.7-871