TM 55-1520-240-23-6
7-151
INSTALL UTILITY HYDRAULIC PUMP
(Continued)
7-151
NOTE
Hydraulic Pump P/N 938555
(145HS100-3) is no longer the correct
configuration after completion of ECP
D213 and turnaround program (TB
1-1520-240-20-75). The correct P/N
is 145HS100-4.
1.
Install elbow (1), packing (2), and nut (3) in port
(4). Remove tag.
2.
Install union (5) and packing (6) in OUT port (7).
3.
Install reducer (8) and packing (9) in IN port (10).
3.1.
Install union (11) and packing (12) in port (13).
4.
Cap elbow (1) union (5), reducer (8) and union
(11) and ports (7, 10, and 13).
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Do not install pump with dry case.
This can cause internal damage to
pump.
5.
Fill pump case (14) with clean hydraulic fluid
(E199) through case drain port (15). Cap port.
Wear gloves (E184.1).
6.
Remove protective material from spline (16).
7.
Coat entire surface of packing (15.1) and splines
(15) with grease (E190). Install packing on
spline. Wear gloves (E184.1).
8.
Remove protective cover from mount.