TM 55-1520-240-23-6
7-133
INSTALL FORWARD SWIVELING SERVOCYLINDER
(Continued)
7-133
25.
From passageway, connect hose (60) to tee (61).
Remove tag.
26.
Connect hose (62) to tee (63). Remove tag.
INSPECT
FOLLOW-ON MAINTENANCE:
Connect forward pitch links (Task 5-99).
Bleed flight control hydraulic system (Task 7-16).
Perform operational check (TM 55-1520-240-T).
Perform neutral rigging check (Task 11-33).
Install forward transmission drip pan (Task 2-3).
Close left forward work platform (Task 2-2).
END OF TASK
7-601