TM 55-1520-240-23-6
7-109
REMOVE NO. 1 OR NO. 2 FLIGHT CONTROL RESERVOIR/COOLER TEMPERATURE
BULB
(Continued)
7-109
NOTE
Procedure is same to remove
temperature bulb from No. 1 or
No. 2 flight control reservoir/cooler.
Removal of No. 2 temperature bulb is
shown here.
1.
Open valve (1) and drain reservoir/cooler (2)
through drain (3). Use container and cloths
(E135) for spilled fluid. Use gloves (E186).
2.
Close valve (1).
3.
Disconnect electrical connector (4) from bulb (5).
4.
Remove lockwire from valve (6), bulb (5), and
switch (7).
5.
Remove bulb (5) and packing (8) from
reservoir/cooler (2). Use cloths (E135) for spilled
fluid.
NO BREAK - WORK HARDER
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-509