TM 55-1520-240-23-6
7-97
EXTENSIBLE LINK ACTUATOR CYLINDER FUNCTIONAL TEST (AVIM)
(Continued)
7-97
Cover is spring-loaded. Remove with
caution. Otherwise personal injury
can occur.
7.
Remove two screws (11) and wing nuts (12) from
adapter (5).
8.
Remove lockwire from four screws (13).
9.
Remove two opposing screws (13).
10.
Install two screws (11) with wing nuts (12).
Tighten wing nuts against cover (14).
11.
Remove remaining two screws (13).
12.
Loosen two wing nuts (12). Remove two screws
(11).
13.
Tag and remove cover (14) and packing (15).
Set cover aside.
Acetone (E20) is flammable and toxic.
It can irritate skin and cause burns.
Use only in well-ventilated area, away
from heat and open flame. In case
of contact, immediately flush skin or
eyes with plenty of water for at least
15 minutes. Get medical attention
for eyes.
14.
Clean authority cover 145GS278-12 (16) with
acetone (E20). Use gloves (E186).
15.
Position cover (16) and packing (15) on
extensible link (8). Install two screws (13) with
wing nuts (12). Tighten wing nuts until cover
seats.
16.
Install two screws (13).
17.
Remove two screws (11) with wing nuts (12).
18.
Install remaining two screws (13).
19.
Connect No. 1 AFCS cable 145GS278-5 (17)
between AFCS 1 receptacle (18) and extensible
link receptacle (19).
7-379