TM 55-1520-240-23-6
7-95
REMOVE EXTENSIBLE LINK SERVO VALVE (AVIM)
7-95
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Insertion/Extraction Tool, M83723/31-20
Materials:
Paper Tags (E264)
Cloths (E135)
Gloves (E186)
Personnel Required:
Aircraft Pneudraulics Repairer
Equipment Condition:
Off Helicopter Task
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
7-372